| Model |
PH-16FSN (Natural Gas)
/ PH-16FSP (L.P. Gas) |
| Purpose |
Domestic Hot Water Supply
Only / Residential Use Only |
| Rated Gas Input (Btu/Hr.)
|
31,500 (Min.) - 118,000
(Max.) |
| Dimensions, W x H x D |
13 3/4" x 22 1/4"
x 5 1/8" |
| Net Weight (Ibs.)
|
35 |
| Installation |
Indoor Wall Mounting Type
(Forced Exhaust, Fan Assisted)
Side wail venting for positive pressure and possible condensation
With an optional vent trap for vertical venting (Max. 16 feet 5 inches)
|
| Working Water Pressure |
14 psi (Min.) - 150 psi
(Max.) |
| Minimum Water Flow |
0.92 Gallon/Minute
|
| Gas Connection |
1/2" NPT Female (w/supplied
Gas Shutoff Valve) |
| Water Connection |
3/4" NPT Male
|
| Vent Size |
3"
Special Certified Stainless Steel Venting |
| Efficiency Rating |
80% |
| Inlet Gas Pressure before water heater
|
Natural Gas: Min. 4.0"
w.c. Max. 10.5" w.c.
L.P. Gas: Min. 8.0" w.c. Max. 14.0" w.c.
(Do not exceed maximum pressure.) |
| Hot Water Supply |
Adjusting Range |
100œF~120œF |
| Combustion |
System |
Fan Assisted Combustion |
| Main Burner |
Bunsen Type Burner |
| Ignition |
Electric Continuous Sparking
|
| Electrical Portion
|
Electrical Rating |
120 V / 60 HZ, Less than 2 Amps
|
| Wire |
3 (three) Pin Power Supply Cord 10
Feet |
| Fuse |
3 A Fuse x 2 |
| Fan Motor |
Sirocco Fan |
| Safety Devices
|
Oxygen Depletion Safety Device
|
Sensing Burner |
| Flame Failure Safety Device
|
Flame Rod Type |
| Over Heat Limiter for Heat Exchanger
|
Film Type for Entire Heat Exchanger
|
| Air Flow Switch |
Diaphragm Type Pressure Switch |
| Max. Vent Pipe Extension |
3" Diameter, 33 Feet 3
(three) 90 Degree Elbows |
| Controlling System |
Water Volume Sensing Device,
Water Volume Servo, Freeze Protection Electric Heater, Gas Pressure Regulator
|
| Optional Accessory |
Paloma Condensate Trap
for Vertical Venting |