Metlund D'MAND Systems
Water Recirculation System [S-50T, S-70T, S-02T]
The METLUND D'mand® System is designed to move the hot
water from your most remote fixture on D'mand® within seconds and can be installed
in either an existing home or a new home.
FEATURES
Life Expectancy of 14-20 Years
Energy Star Credit
Operates with Tankless or Tank Water Heaters
Five Year Warranty
IAPMO Listing
UL Listed - US/Canada
Receives Green Building LEED Credits
Tested and Proven by the US Dept. of Energy to save both water and energy
Less than $1/yr to operate
System only operates when there is a demand for hot water
Title 24 Compliance (CA only)
Simple Installation for New and Existing Homes
To download PDFs, right click on the link and choose "Save Target As"
INSTALLATION OPTIONS
In an existing home - The D’MAND® System is designed
to move the hot water from your water heater to your most remote fixture (kitchen,
master bath, stc.) within seconds. At the push of a button, the cool water you
normally let run down the drain is circulated back to the water heater through
the cold water line. The D’MAND® System is easily installed under the sink farthest
from your water heater. At your D’MAND®, the pump pulls the hot water from the
water heater moving only the cold water back through the cold water line into
the water heater to replace the hot water being moved. When the hot water arrives
at The D’MAND® System it is automatically shut off by a thermo sensor at a 3 to
5 degree temperature change.
- Download the installation diagram here(561Kb, pdf)
In a new home - There are two options for Structured
Plumbing, both using the S-Series Metlund D’MAND® System. The first option is
to locate the S-Series pump and the thermo sensor at the fixture furthest from
the water heater. The second option is to locate the S-Series pump at the water
heater and extend the thermo sensor from the electronic control board back to
the fixture furthest from the water heater. Both options can be activated by hand
with buttons, remote wireless buttons or motion sensor. Both the S-Series pump
and the thermo sensor should be installed on the dedicated return line pipe. When
hot water is demanded, using any of our activation methods, the Metlund D’MAND®
System brings hot water rapidly to the farthest fixture from the water heater
where the sensor will pick up the temperature rise and send a signal to turn the
pump off. This concept prevents the hot water passing the thermo sensor, thus
saving lost energy in the dedicated return line.
-
Download the installation diagram here (577Kb, pdf)
The Options - There are three basic models of the
METLUND D'Mand® System, the S-50T, S-70T and the S-02T series. Please see the
table below for examples of available options.
MODEL
SPECIFICATIONS
S-50T-PF-R (As Shown)
8 gallons per minute flow
12 feet of head
1/45 horse power
.55 AMPS
3 YEAR WARRANTY
S-70T-PF-R(As Shown)
14 gallons per minute flow
16 feet of head
1/25 horse power
.76 AMPS
5 YEAR WARRANTY
S-02T-PF-R (As Shown)
26 gallons per minute flow
32 feet of head
1/12 horse power
1.70 AMPS
Valve 300psi system pressure
32° F to 250° F
5 YEAR WARRANTY
Tankless Water Heater Specifications
S-70T
S-02T
Standard Plumbing AND distance between Tankless
water heater and fixture where D'MAND system is installed.
Under 60 feet
Over 60 feet
Re-Circulating plumbing AND square footage of house
Under 2500 sq. ft.
Over 2500 sq. ft.
Ordering - Now that you've had a chance to take a
look at a few of the available options, scroll down to find the system that best
fits your need.
S-50T1/2" mip, button, for use with dedicated return lines